2.
Rev. bras. anal. clin ; 53(2): 180-182, 20210630. ilus
Article in Portuguese | LILACS | ID: biblio-1352922

ABSTRACT

Desde o primeiro caso de COVID-19, ocorrido na China em dezembro de 2019, o espec- tro da doença tem se mostrado muito amplo, incluindo uma miríade de manifestações hematológicas. Relatamos aqui o caso de um paciente com diagnóstico confirmado de COVID-19, o qual apresentou, no sangue periférico, a presença de hemácias apresentan- do projeções citoplasmáticas, semelhantes a uma célula pinçada (pincer cells), também conhecidas como hemácias em forma de cogumelo (mushroom-shaped red blood cells).


Since the first case of COVID-19, which occurred in China in December 2019, the spectrum of the disease has been very broad, including a myriad of hematological manifestations. We report here the case of a patient with a confirmed diagnosis of COVID-19, who presented, in peripheral blood, the red blood cells with cytoplasmic projections, similar to a pincer cells, also known as mushroom-shaped red blood cells.


Subject(s)
Humans , Male , Adult , Oxidative Stress , Severe acute respiratory syndrome-related coronavirus , Erythrocytes , Cytokine Release Syndrome , COVID-19
3.
Rev. bras. anal. clin ; 53(1): 85-89, 20210330. ilus
Article in Portuguese | LILACS | ID: biblio-1291762

ABSTRACT

Introdução: Após tratamento para Mieloma Múltiplo (MM), a transformação em linfoma de burkitt (LB) é incomum, com raros casos relatados.Objetivo: relatar um caso raro de LB secundário a MM, em paciente tratado com protocolo CyBorD. Relato de caso: Nós descrevemos um caso de um homem de 37 anos, negro, senegalês e HIV positivo, que em pouco mais de dois meses após o diagnóstico de MM evoluiu para uma transformação medular que resultou em um linfoma linfoblástico B compatível com LB. Conclusão: Este relato de caso demonstra a possibilidade de transformação maligna de MM para LB, incentivando assim futuras comparações multicêntricas de casos similares num esforço amplo para uma melhor definição desse processo patológico.


Introduction: After treatment for Multiple Myeloma (MM), transformation into burkitt's lymphoma (LB) is uncommon, with rare cases reported. Objective: to report a rare case of LB secondary to MM, in a patient treated with the CyBorD protocol. Case report: We describe a case of a 37-year-old man, black, Senegalese and HIV positive, who in just over 2 months after the diagnosis of MM evolved to a medullary transformation that resulted in a B lymphoblastic lymphoma compatible with LB. Conclusion: This case report demonstrates the possibility of malignant transformation from MM to BL, thus encouraging future multicentric comparisons of similar cases in a broad effort to better define this pathological process.


Subject(s)
Humans , Male , Adult , Burkitt Lymphoma , Multiple Myeloma
4.
J. Bras. Patol. Med. Lab. (Online) ; 55(3): 267-280, May-June 2019. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1012485

ABSTRACT

ABSTRACT Introduction: Diagnosing infections in intensive care unit (ICU) patients is vital to provide appropriate therapies. Hematological analyzers perform automated immature granulocyte counts (IG) quickly and with no additional cost when compared to traditional microbiological cultures. Elevated IG is directly associated with infections and inflammation. Objectives: Evaluate IG as infection marker in adult inpatients at the ICU-Complexo Hospital de Clínicas da Universidade Federal do Paraná (CHC-UFPR), compared to cultures of biological materials (gold standard). Material And Methods: Samples of 200 adult inpatients at CHC-UFPR ICU with suspected infection were used. Absolute (IG#) and relative (IG%) counts were performed on the Sysmex XN-3000. Cultures and blood cultures were performed either manually or on Bactec FX. Diagnostic accuracy and agreement for IG# and IG% were evaluated. Results: The reference intervals (RI) obtained for IG# and IG% were 0.06 × 103/µl and 0.6%, respectively, with sensitivity for both of 74.4% and specificity of 25.3% for IG#, and 26.6% for IG%. The receiver operating characteristic (ROC) curve showed cut-off value of 0.33 × 103/µl for IG#, sensitivity of 28%, specificity of 82.3%, and area under the curve (AUC) of 0.521. For IG%, cut-off value was 1.35%, sensitivity 44.6%, specificity 64.6%, and AUC 0.532. CV < 3% increased specificity to 88%. Conclusion: RI of IG% and IG# showed high sensitivity and are useful in screening for infection in ICU patients. The CVs demonstrated by the ROC curves showed high specificity and are helpful on the exclusion of sepsis diagnosis in ICU patients. IG was shown to be useful for screening and confirmation of infection in ICU patients.


RESUMEN Introducción: Diagnosticar infecciones en pacientes de la unidad de cuidados intensivos (UCI) es de suma importancia para proporcionar el tratamiento adecuado. El contaje automatizado de granulocitos inmaduros (GI) en analizadores hematológicos es rápido y sin costes adicionales. La elevada tasa de GI está asociada a infecciones. Objetivos: Evaluar GI como indicador de infección en pacientes adultos de la UCI del Complexo Hospital de Clínicas da Universidade Federal do Paraná (CHC-UFPR) en comparación a culturas de materiales biológicos (estándar de oro). Material Y Métodos: Se analizaron muestras de 200 pacientes adultos con sospecha de infección de la UCI del CHC-UFPR. Los conteos automatizados de granulocitos inmaduros absolutos (GI#) e relativos (GI%) se realizaron en el Sysmex-XN-3000, y los cultivos y hemocultivos, manualmente o en el Baetec-FX. Se han evaluado precisión diagnóstica y concordancia para GI# y GI%. Resultados: Los rangos de referencia obtenidos para GI# y GI% fueron 0,06 × 103/µl y 0,6%, respectivamente, con sensibilidad para ambos de 74,4% y especificidad de 25,3% para IG# y 26,6% para IG%. La curva receiver operating characteristic (ROC) ha mostrado valor de corte de 0,33 × 103/µl para IG#, sensibilidad de 28%, especificidad de 82,3% y área bajo la curva (AUC) de 0,521. Para GI%, el valor de corte ha sido 135%, sensibilidad de 44,6%, especificidad de 64,6% y AUC de 0,532. Valores de corte de GI% < 3% aumentaron la especificidad para 88%. Conclusión: Rangos de referencia de GI% y GI# presentaron sensibilidad elevada y son útiles en el triaje de infecciones en pacientes de UCI. Los valores de corte enseñados por las curvas ROC presentaron alta especificidad, permitiendo la identificación adecuada de los pacientes sanos. GI se ha mostrado útil para triaje y confirmación de infección en pacientes de UCI.


RESUMO Introdução: Diagnosticar infecções em pacientes da unidade de terapia intensiva (UTI) é vital para implementar terapias apropriadas. A contagem automatizada de granulócitos imaturos (IG) em analisadores hematológicos é rápida e sem custos adicionais. A taxa de IG elevada está associada a infecções. Objetivos: Avaliar IG como indicador de infecção em pacientes adultos da UTI do Complexo Hospital de Clínicas da Universidade Federal do Paraná (CHC-UFPR) em comparação com culturas de materiais biológicos (padrão-ouro). Material E Métodos: Foram analisadas amostras de 200 pacientes adultos com suspeita de infecção da UTI do CHC-UFPR. As contagens automatizadas de granulócitos imaturos absolutas (IG#) e relativas (IG%) foram realizadas no Sysmex-XN-3000, e as culturas e as hemoculturas, manualmente ou no Bactec-FX. As características de desempenho de teste diagnóstico para IG# e IG% foram avaliadas. Resultados: Os intervalos de referência (IR) obtidos para IG# e IG% foram 0,06 × 103/µl e 0,6%, respectivamente, com sensibilidade para ambos de 74,4% e especificidade de 25,3% para IG# e 26,6% para IG%. A curva receiver operating characteristic (ROC) mostrou valor de corte de 0,33 × 103/µl para IG#, sensibilidade de 28%, especificidade de 82,3% e área sob a curva (AUC) de 0,521. Para IG%, o valor de corte foi de 1,35%, sensibilidade de 44,6%, especificidade de 64,6% e AUC de 0,532. Valores de corte de IG% < 3% aumentaram a especificidade para 88%. Conclusão: IRs de IG% e IG# apresentaram sensibilidade elevada e são úteis na triagem de infecção nos pacientes da UTI. Os VCs demonstrados pelas curvas ROC para IG% e IG# apresentaram elevada especificidade, sendo, portanto, úteis para exclusão de diagnóstico de sepse nos pacientes da UTI. IG mostrou-se útil para triagem e confirmação de infecção em pacientes de UTI.

5.
Rev. bras. hematol. hemoter ; 39(4): 306-317, Oct.-Dec. 2017. tab, graf
Article in English | LILACS | ID: biblio-898957

ABSTRACT

Abstract Background: There is great interest in reducing the number of automated complete blood counts requiring manual blood smear reviews without sacrificing the quality of patient care. This study was aimed at evaluating and establishing appropriate screening criteria for manual blood smear reviews to improve the performance in a hematology laboratory. Method: A total of 1977 consecutive samples from the daily workload were used to evaluate four sets of screening criteria for manual blood smear reviews to identify samples with positive smear findings. Three sets of screening criteria were arbitrarily proposed in this study: Group 1 (narrow ranges), Group 2 (intermediate ranges), and Group 3 (wide limits) and one set (Group 4) was adapted from the International Society for Laboratory Hematology. All samples were run on Sysmex hematology analyzers and were investigated using manual blood smear reviews. Diagnostic accuracy and agreement were performed for each set of screening criteria, including an investigation of microscopic review rate and efficiency. Results: The microscopic review rates for Groups 1, 2, 3 and 4 were 73.85%, 54.52%, 46.33% and 46.38%, respectively; the false-negative rates were 0.50%, 1.97%, 2.73% and 3.95%, respectively. The efficiency and negative predictive values of Group 3 were 73.04% and 4.91%, respectively. Conclusions: Group 3 had the best relationship between safety (false-negative rate: ≤3%) and efficiency to estimate the limits of automation in performing complete blood counts. This study strengthens the importance of establishing screening criteria for manual blood smear reviews, which account for the different contexts in which hematological determinations are performed. Each laboratory should optimize the screening criteria for manual blood smear reviews in order to maximize their efficiency and safety.


Subject(s)
Blood Cell Count , Hematologic Tests , Data Interpretation, Statistical , False Negative Reactions
6.
J. Bras. Patol. Med. Lab. (Online) ; 53(3): 150-158, May.-June 2017. tab, graf
Article in English | LILACS | ID: biblio-954366

ABSTRACT

ABSTRACT Introduction: Body fluid (BF) analysis is critical to the diagnosis and monitoring of several pathological conditions. The limitations of manual cell counts have led to greater interest in the development of automated BF analysis. Objective: To evaluate the analytical performance of the Sysmex XE-5000 hematology analyzer in the analysis of pleural and ascitic fluids in the laboratory routine of a large university hospital. Methods: A total of 56 samples (35 ascitic and 21 pleural fluids) were analyzed by manual optical microscopy (OM) and XE-5000. Analytical performance includes linearity, carryover, functional sensitivity and comparison of patient samples. Results: Performance studies showed linearity up to 25,825 WBC-BF/µl (r2 = 0.999), WBC-BF showed carryover of 0.18%, and the lower limit of quantitation was set at 22 WBC-BF/µl. Good correlations between the methods were observed just for total cell (TC-BF) and white blood cell (WBC-BF) counts in pleural and ascitic fluids. The high-fluorescence cell count (HF-BF) showed poor correlation but high positive predictive value (PPV) for both fluids (94.74% for pleural and 96.97% for ascitic fluid). Conclusion: XE-5000 provides accurate and precise count for TC-BF, WBC-BF and polymorphonuclear cells (PMN-BF) in pleural and ascitic fluids in medical decision levels, but the morphological differentiation should continue to be held by OM. Histogram and scattergram displayed on XE-5000 must always be analyzed to assess if there is any interference or flag. The HF-BF parameter is a potential tool for screening.


RESUMO Introdução: A análise de líquidos corporais é fundamental para o diagnóstico e o acompanhamento de várias condições patológicas. Devido às limitações da contagem manual de células, tem ocorrido maior interesse no desenvolvimento da análise automatizada de líquidos corporais. Objetivo: Verificar o desempenho analítico do analisador hematológico Sysmex XE-5000 na análise de fluidos pleurais e ascíticos na rotina laboratorial de um hospital universitário de grande porte. Métodos: Um total de 56 amostras (35 de líquidos ascíticos e 21 de líquidos pleurais) foi analisado por microscopia ótica manual (MOM) e pelo XE-5000. O estudo de verificação incluiu linearidade, carryover, limite de quantificação e comparação de amostras de pacientes. Resultados: O estudo de verificação mostrou linearidade de até 25.825 WBC-BF/ml (r2 = 0,999); WBC-BF, carryover de 0,18%; e o menor limite de quantificação foi fixado em 22 WBC-BF/ml. Boas correlações entre o método manual e o automatizado foram observadas apenas para as contagens de total de células nucleadas (TC-BF) e glóbulos brancos (WBC-BF) em líquidos pleurais e ascíticos. A contagem de células de alta fluorescência (HF-BF) mostrou correlação fraca, porém valor preditivo positivo (VPP) elevado para ambos os líquidos corporais (94,74% pleural; 96,97% ascítico). Conclusão: O XE-5000 fornece contagem confiável para TC-BF, WBC-BF e células polimorfonucleares (PMN-BF) em fluidos pleurais e ascíticos em níveis de decisão médica, contudo a diferenciação morfológica deve continuar a ser realizada por MOM. O histograma e o diagrama de dispersão exibidos no XE-5000 devem ser sempre avaliados quanto à existência de qualquer interferência ou alerta suspeito. A contagem de HF-BF constitui uma potencial ferramenta para triagem.

8.
Rev. bras. hematol. hemoter ; 36(3): 219-225, May-Jun/2014. tab
Article in English | LILACS | ID: lil-713673

ABSTRACT

OBJECTIVE: to verify whether the review criteria for automated blood counts suggested by the International Consensus Group for Hematology Review of the International Society for Laboratory Hematology are suitable for the Hematology Laboratory of Hospital de Clinicas, Universidade Federal do Paraná. METHODS: initially, the review criteria of the International Society for Laboratory Hematology were adapted due to limitations in the Institution's electronic hospital records and interfacing systems. The adapted review criteria were tested using 1977 samples. After this first assessment, an additional 180 inpatient samples were analyzed to evaluate the screening criteria of the review criteria in conjunction with positive smear findings established by the institution. The performance of the review criteria was verified by determining false positive, false negative, true positive and true negative rates, sensitivity, specificity, positive predictive value, negative predictive value, microscopic review rate and efficiency. RESULTS: initial analysis showed false negatives = 6.73%, false positives = 23.27%, microscopic review rate = 46.03% and efficiency = 70.0%. An evaluation of the screening criteria adapted from the review criteria together with the positive smear findings of the institution showed false negatives = 15.5%, false positives = 10.5%, microscopic review rate = 37.3% and efficiency = 73.8%. In both situations the safety limit (false negative <5%) recommended by the review criteria was exceeded. CONCLUSIONS: the review criteria adapted from the International Society for Laboratory Hematology are neither suitable nor safe for use in the hematology laboratory of the Hospital de Clinicas. This implies a need to develop and validate institution-specific review criteria in order to decrease false negative results to an acceptable and safe rate for patients. .


Subject(s)
Humans , Automation , Blood Cell Count , Validation Study , Hematology
9.
J. bras. patol. med. lab ; 50(1): 26-35, 02/2014. tab, graf
Article in English | LILACS | ID: lil-704695

ABSTRACT

Introduction: The Sysmex® XE-2100D is a multiparameter hematology analyzer designed for hematology testing in samples with ethylenediamine tetraacetic acid (EDTA). Objectives: Considering the importance of this hematology analyzer for clinical and laboratory practice, the objective of this study was to evaluate its analytical performance, comparing the obtained results with quality specifications described in literature. Material and method: In the evaluation of analytical performance, according to recommendations of the document H26-A2 of the Clinical and Laboratory Standards Institute (CLSI), intra-run imprecision, inter-run imprecision, linearity, carryover, autosampler evaluation, clinical sensitivity of the atypical lymphocytes flag (n = 400 samples) were included, as well as the comparison between automated and manual leukocyte differential count (n = 400 samples), based on an adaptation of the document H20-A2 of CLSI. Results: Repeatability, reproducibility, linearity and carryover were satisfactory according to the manufacturer's specifications. The clinical sensitivity of the atypical lymphocytes flag showed efficiency, sensitivity and specificity of 92.5%, 65.2% and 94.1% respectively. The correlation coefficients between the automated and manual differential counts of neutrophils, lymphocytes, monocytes, eosinophils and basophils were 0.991, 0.99, 0.872, 0.974 and 0.557, respectively. Conclusions: The results were in accordance with quality specifications described in literature, indicating reliability in Sysmex® XE-2100D. This fact ensures certainty to both laboratory professionals and medical staff. We conclude that the Sysmex® XE-2100D showed excellent analytical performance, and is useful to provide reliable hematology data...


Introdução: O Sysmex® XE-2100D é um analisador hematológico multiparamétrico destinado à realização de testes hematológicos em sangue anticoagulado com ácido etilenodiamino tetra-acético (EDTA). Objetivos: Considerando a sua importância na prática clínica e laboratorial, o objetivo deste estudo foi avaliar seu desempenho analítico, comparando os resultados obtidos com especificações de qualidade descritas na literatura. Material e método: Na avaliação de desempenho analítico, conforme recomendações do documento H26-A2 do Clinical and Laboratory Standards Institute (CLSI), foram incluídos ensaios de verificação da imprecisão intraensaio ou repetitividade, imprecisão entre ensaios ou reprodutibilidade, linearidade, carryover (arraste), avaliação do mecanismo homogeneizador de amostras, sensibilidade clínica do alerta morfológico (flag) de linfócitos atípicos (n = 400 amostras) e a comparação entre a contagem diferencial de leucócitos automatizada e a manual (n = 400 amostras), baseada em uma adaptação do documento H20-A2 do CLSI. Resultados: Os ensaios de verificação da repetitividade, reprodutibilidade, linearidade, carryover (arraste) foram satisfatórios conforme especificações do fabricante. O ensaio de sensibilidade clínica do alerta morfológico (flag) de linfócitos atípicos mostrou eficiência, sensibilidade e especificidade de 92,5%; 65,2% e 94,1% respectivamente. Os coeficientes de correlação entre as contagens diferenciais automatizadas e manuais de neutrófilos, linfócitos, monócitos, eosinófilos e basófilos foram de 0,991; 0,99; 0,872; 0,974 e 0,557 respectivamente...


Subject(s)
Humans , Automation, Laboratory/methods , Automation, Laboratory/standards , Quality Control , Hematologic Tests/methods , Hematologic Tests/standards
10.
J. bras. patol. med. lab ; 49(5): 324-331, Oct. 2013. ilus, tab
Article in English | LILACS | ID: lil-697107

ABSTRACT

INTRODUCTION AND OBJECTIVE: To evaluate the performance of red cell distribution width reported statistically as coefficient of variation (RDW-CV), standard deviation (RDW-SD), and mathematical deduction of 1 standard deviation (SD) around mean corpuscular volume (MATH-1SD) in identifying anisocytosis in automated blood counts when compared with the manual quantification of erythrocyte anisocytosis in peripheral blood smears. MATERIAL AND METHODS: 806 routine samples obtained from the hematology laboratory of Hospital de Clínicas da Universidade Federal do Paraná (HC-UFPR) were analyzed. Performance evaluations were carried out by dividing samples into microcytic, normocytic and macrocytic mean corpuscular volume (MCV). For each MCV range, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and efficiency were calculated. In addition, the Youden index (Y) was obtained and a comparative analysis with receiver operating characteristic (ROC) curves was done to evaluate the performance of RDW-SD, RDW-CV, and MATH-1SD on different MCV ranges. RESULTS AND DISCUSSION: RDW-CV had the best sensitivity (86.8%) and efficiency (86.8%) in detecting anisocytosis in microcytic MCV ranges. RDW-SD and MATH-1SD were more sensitive and efficient in normocytic (82.9% and 83.3%; 92.1% and 92.3%, respectively) and macrocytic (90.2% and 90.2%; 95.1% and 95.1%, respectively) MCV ranges. A ROC curve analysis indicated that RDW-CV was more efficient in detecting anisocytosis in microcytic MCV ranges (p < 0.05 vs. RDW-SD and MATH-1SD). In normocytic and macrocytic MCV ranges, RDW-SD and MATH-1SD showed similar efficiency in detecting anisocytosis (p < 0.05 vs. RDW-CV). CONCLUSION: RDW-SD, RDW-CV, and MATH-1SD deliver different performances in detecting blood smear anisocytosis according to MCV values. They are parameters that complement each other and should be used together to identify erythrocyte size heterogeneity.


INTRODUÇÃO E OBJETIVO: Avaliar o desempenho do red cell distribution width expresso em coeficiente de variação (RDW-CV) e desvio padrão (RDW-SD) e da dedução matemática de 1 desvio padrão (DP) ao redor do volume corpuscular médio (MATH-1SD) ao identificar anisocitose nos hemogramas automatizados, quando comparados com o método manual de quantificação da anisocitose eritrocitária em lâmina. MATERIAL E MÉTODOS: Foram analisadas 806 amostras obtidas da rotina laboratorial da Seção de Hematologia do Hospital de Clínicas da Universidade Federal do Paraná (HC-UFPR). As avaliações de desempenho foram realizadas dividindo-se as amostras em volume corpuscular médio (VCM) microcítico, VCM normocítico e VCM macrocítico. Para cada faixa de VCM, sensibilidade, especificidade, valor preditivo positivo (VPP), valor preditivo negativo (VPN) e eficiência foram determinados. Além disso, o índice de Youden foi calculado e uma análise comparativa de curvas de características de operação do receptor (curvas ROC [receiver operating characteristic]) foi realizada para verificar o desempenho de RDW-CV, RDW-SD e MATH-1SD em diferentes faixas de VCM. RESULTADOS E DISCUSSÃO: O RDW-CV obteve a melhor sensibilidade (86,8%) e eficiência (86,8%) ao detectar anisocitose em faixas de VCM microcítico. O RDW-SD e o MATH 1SD foram mais sensíveis e eficientes em VCM normocítico (82,9% e 83,3%; 92,1% e 92,3%, respectivamente) e macrocítico (90,2% e 90,2%; 95,1% e 95,1%, respectivamente). A comparação de curvas ROC demonstrou que o RDW-CV foi mais eficiente ao detectar anisocitose em VCM microcítico (p < 0,05 vs. RDW-SD e MATH-1SD). Em VCM normocítico e macrocítico, o RDW-SD e o MATH-1SD mostraram eficiência semelhante ao detectar anisocitose (p < 0,05 vs. RDW-CV). CONCLUSÃO: RDW-CV, RDW-SD e MATH-1SD possuem desempenhos diferentes ao detectar anisocitose em lâmina conforme a faixa de VCM. São parâmetros que se complementam e que devem ser utilizados em conjunto na identificação de heterogeneidade dos tamanhos eritrocitários.

11.
Rev. bras. anal. clin ; 43(3): 237-244, 2011. tab, graf
Article in Portuguese | LILACS | ID: lil-651511

ABSTRACT

O Sysmex® CA-1500 é um analisador automatizado de coagulação que detecta a formação de fibrina por princípio ótico.A avaliação do seu desempenho analítico foi realizada através de testes de precisão, reprodutibilidade, arraste e linearidade, além de ensaios para verificar a influência de fatores pré-analíticos como relação anticoagulante / sangue e hemólise nas determinações deTP, TTP, TT e fibrinogênio. Além disso, os resultados de TP e TTP foram correlacionados com os obtidos no coagulômetro ST4, Diagnostica STAGO, que utiliza o método eletromagnético para a detecção do coágulo de fibrina. Observou-se grande variação dosresultados sobre a influência da hemólise (TP: 0,91 a 2,33%; TTP: 1,37 a 6,54% e TT: 1,38 a 12,72%) e relação anticoagulante/sangue (TP: 1,39 a 659,3%; TTP: 2,93 a 275,2%, TT: 4,0 a 128% e fibrinogênio: 3,4 a 32,2%), quando comparados com amostras sem hemólise e com a relação anticoagulante /sangue de 1:9. A porcentagem de arraste foi (TP: 0,75%, TTP: 0,50% e fibrinogênio: 5,65%). Aprecisão intraensaio para TP, TTP, TT e fibrinogênio obteve CV < 3% para plasmas normais e patológicos, assim como a reprodutibilidade interensaios em plasma normal liofilizado e pool de plasmas de pacientes normais. As correlações para TP e TTP entre os doiscoagulômetros avaliados obteve valores de r ≥ 0,90. A linearidade foi boa até aproximadamente 650 mg/dL de fibrinogênio e obteve r = 0,981. Os resultados obtidos demonstraram que o CA-1500 realiza os testes de coagulação com desempenho analítico satisfatório.


The Sysmex® CA-1500 is an automated coagulation analyzer that detects the formation of fibrin clot by optical principle.The evaluation of its analytical performance was accomplished through tests of precision, reproducibility, linearity and carryover, as well as tests to check the influence of pre-analytical factors such as the anticoagulant / blood ratio and hemolysis on the determinations of PT, PTT, TT and fibrinogen. Moreover, the results of PT and PTT were correlated with those obtained in the ST4 coagulometer, Diagnostica Stago, using the eletromagnetic method for the detection of fibrin clot. We found great variation inresults under the influence of hemolysis (PT: 0,91 to 2,33%, PTT: 1,37 to 6,54% and TT: 1,38 to 12,72%) and anticoagulant / blood ratio (PT: 1,39 to 659,3%, PTT: 2,93 to 275,2%, TT: 4,0 to 128% and fibrinogen: 3,4 to 32,2%) compared with samples withouthemolysis and the ratio of 1:9 anticoagulant / blood. The percentage of carryover was (PT: 0,75%, PTT: 0,50% and fibrinogen: 5,65%). The intra-assay precision for PT, PTT, TT and Fibrinogen had CV < 3% for normal and abnormal plasmas, as well as interassayreproducibility in normal lyophilized plasma and normal pooled plasma. The correlations between TP and TTP on the two evaluated coagulometers obtained r values ≥ 0,90. The linearity was good up to about 650 mg/dl of fibrinogen and obtained r = 0,981. The results showed that CA-1500 perform coagulation tests with satisfactory analytical performance.


Subject(s)
Humans , Adult , Automation, Laboratory , Automation, Laboratory/instrumentation , Quality Control , Blood Coagulation Tests/methods
13.
Rev. bras. anal. clin ; 32(3): 191-4, 2000. graf
Article in Portuguese | LILACS | ID: lil-296348

ABSTRACT

Controles comerciais para todas as medidas hematológicas só se tornaram disponíveis no início da década de 60, sendo que ainda há falta de padronizaçäo apropriada para diversas medidas envolvendo componentes celulares. As amostras comerciais de células consistem de células de sangue humano ou de outros animais, alteradas para retardar a deterioraçäo. De um modo geral, os fabricantes utilizam para essas células os termos: fixadas, tamponadas, estabilizadas ou preservadas, para indicar o seu processo de preparo, sem contudo descrevê-lo. Em trabalhos anteriores, desenvolveu-se amostras adequadas ao controle de qualidade em hematimetria, estáveis para os valores do eritrograma durante 100 dias, pela preservaçäo de eritrócitos em meio CE, composto por glicose, NaCl, citrato de sódio, fosfato monohidrógeno de sódio, KCl, EDTANa2, albumina bovina, clormicetina, neomicina e cortisona e pela fixaçäo parcial com glutaraldeído [ Leonart, Rev. Bras. Anál. Clín. 21: 111, 1989 ]. O uso de soluçöes aditivas para o armazenamento de concentrados de plaquetas tem aumentado durante os últimos anos e se tornado frequente na prática clínica. Em testes preliminares, realizados com o meio CE para a preservaçäo de plaquetas humanas, observamos estabilidade para a sua contagem durante até 35 dias [ Emendörfer et al, Rev. Bras. Anál. Clín. 31:18, 1999]. A partir de 20 amostras de sangue venoso em EDTAK2 e da obtençäo do plasma rico em plaquetas, testou-se a fixaçäo parcial em glutaraldeído, com posterior ressuspensäo das plaquetas em meio CE, obtendo-se valores estáveis para contagem em Coulter Counster T890 durante até 50 dias. Foram estudadas modificaçöes na composiçäo do meio CE nas concentraçöes de 1 a 6 g/gL de albumina bovina, obtendo-se maior estabilidade para as amostras de plaquetas preservadoras na concentraçäo de 6 g/dL, como empregada no meio CE original. No entanto, em amostras fixadas com glutaraldeído näo se observou diferenças na contagem das plaquetas durante 50 dias, independentemente da concentraçäo de albumina bovina. Os resultados obtidos sugerem que a fixaçäo parcial com glutaraldeído pode ser adequada para a estabilizaçäo de plaquetas em amostras de controle de qualidade.


Subject(s)
Humans , Male , Female , Adult , Blood Platelets/cytology , Glutaral/pharmacokinetics , Quality Control , Culture Media/pharmacokinetics , Blood Preservation/methods
SELECTION OF CITATIONS